How to obtain the FFT data
PreviousHow to use the automatic fault detectionNextHow to configure the frequency of measurements and messages
Last updated
Was this helpful?
By default, the FFT data is turned off on the NEON vibration sensor. To activate the FFT a configuration downlink must be generated and sent via LoRa. Please refer to the configuration section for guidance on how to configure a NEON sensor. The settings to turn on the FFT in the NEON vibration sensor are explained next.
Go to the Schedule Spectrum tab.
Select the command (set to add the configuration, replace to change all FFT settings with the new one, or execute to only do the task once). This step should be skipped if the configuration is done through SolidRed.
Set the timing
Define the vibration settings for the FFT
Select the spectrum type (acceleration, velocity, or envelope)
Set the time to transmit. Generally, it is recommended to set the time to transmit close to the timing.
By applying these settings, the sensor will start measuring and transmitting FFT data periodically based on the established timing.